SOL-010/00 - SOL-015/00
PROTECTION PROBES FOR DIESEL ENGINES
Low radiator fluid level alarm device, for the plastic expansion tank (SOL-010) and the metal expansion tank (SOL-015).FUNCTIONING
SOL-010/00 |
It becomes active when the module is supplied. When the liquid falls below the level of the electrod, this (after 3 seconds) enables an output which can be used by one of our devices or junction box so as to stop the motor. When the liquid returns to the correct level, the output is deactivated automatically. |
SOL-015/00 |
It becomes active when the module is supplied. When the liquid falls below the level of the rod, the latter (after 3 seconds) enables an output which can be used by one of our devices or junction box so as to stop the motor. When the liquid returns to the correct level, the output is deactivated automatically. |
TECHNICAL DATA
- | Battery supply 12 and 24 V |
- | Supply voltage 8÷32 V |
- | Degree of protection for the electronics: IP65 |
- | Degree of protection for the terminal board: IP00 |
ROD TYPE AST-015/00 | |
- | Temperature range -10 ÷ +100°C |
- | Maximum pressure 1 bar |
Type | Code |
SOL-010/00 | 00241022 |
SOL-015/00 | 00241020 |